HomeQIDI X-Plus 3 › HIPS

HIPS settings for the QIDI X-Plus 3

Great match

Quick answer: Print HIPS on the QIDI X-Plus 3 at 240°C hotend, 100°C bed, 126 mm/s, 0% part-cooling fan and 0.8 mm retraction. Run a temperature tower to fine-tune your exact spool.

These are tuned starting settings for printing HIPS on the QIDI X-Plus 3. The QIDI X-Plus 3 has a direct-drive extruder with an all-metal hotend, so we set the hotend to 240°C and the bed to 100°C. HIPS doubles as a light structural material and a limonene-dissolvable support for ABS.

240°C
Hotend
100°C
Bed
126 mm/s
Speed
0%
Part fan

Recommended HIPS profile

Hotend temperature240°C (tower 230–255°C)
Bed temperature100°C
Print speed126 mm/s
Retraction0.8 mm (direct drive)
Part cooling fan0%
Bed adhesionABS slurry or glue; enclosure needed.
NozzleBrass 0.4 mm
DifficultyAdvanced
💡 Best uses for HIPS: dissolvable support for ABS (limonene) and light parts.

Shop HIPS on Amazon →

Troubleshooting HIPS on the QIDI X-Plus 3

ProblemFix
Stringing or fine hairsDry HIPS before printing, drop the hotend a few degrees below 240°C, and raise retraction toward 1.2 mm. Damp filament is the No. 1 cause of stringing.
Poor first-layer adhesionABS slurry or glue; enclosure needed. Re-level the bed, set a slightly squished first layer, and wipe the sheet with IPA so it is grease-free.
Blobs, zits or rough wallsSlow the outer wall, enable coasting/wipe, and keep retraction near 0.8 mm. Keep the part-cooling fan low so layers bond and warping stays down.

FAQ

What temperature should I print HIPS on the QIDI X-Plus 3?
Start at 240°C for the hotend and 100°C for the bed, then run a temperature tower across 230–255°C to dial in your exact filament brand.
What print speed works for HIPS on this printer?
Around 126 mm/s is a safe starting point on the QIDI X-Plus 3. It can go faster once the profile is tuned, but start conservative for clean walls.
What retraction should I use?
Use about 0.8 mm of retraction (direct drive needs very little). If you see stringing, raise retraction speed before distance and dry the filament.
Do I need an enclosure for HIPS on the QIDI X-Plus 3?
Yes — HIPS needs a warm, enclosed chamber, and the QIDI X-Plus 3 is enclosed, so you are ready to go.

Sources & how we tuned this

These settings are community-tested starting points, cross-checked against manufacturer guidance and trusted material references:

Last verified: 2026-07-17. Always run a temperature tower and a small calibration print for your exact spool.